How to maintain the glue filling machine
1. Check if the surface of the equipment is clean and if there are any obvious adhesive residues.
2. Before the homework, was the AB glue weighed and confirmed that the actual total amount of AB material discharged matches the set value.
3. Check the power supply of the equipment and ensure that the wire connections are normal. Also, check if the plug of the wire body is damaged
4. Check if there is any air leakage in the steam source
5. Did the equipment perform automatic cleaning after stopping operation
6. Are the heating and stirring devices functioning properly
7. Check for any glue leakage at all joints, including pumps, joints, pipelines, etc
8. Whether the alarm functions of the equipment are normal. (Upper and lower liquid level, pressure sensor)
9. Does the homework product match the required glue filling ratio Continuously check AB separately, test each value 5-10 times, and finally mix AB 5-10 times, and take the average value. Check if there is any deviation beyond the range.